Pipe Organ Database

a project of the organ historical society

M. P. Möller (Opus 11733, 1986)

Location:

Sacred Heart Convent
916 Convent Rd.
Cullman, AL 35055 US
Sacred Heart Chapel
Organ ID: 27667

Update This Entry

Status and Condition:

  • The organ is unaltered from its original state.
  • The organ's condition is good, in regular use.
We received the most recent update for this instrument's status from Database Manager on May 13, 2018.

Technical Details:

  • Chests: Electro-pneumatic (EP)
  • 10 ranks. 689 pipes. 3 divisions. 2 manuals. 29 stops. 7 registers.
All:
  • Chest Type(s): Electro-pneumatic (EP) chests
  • Position: Exposed pipes or case front visible in a gallery at the rear of the room.
We received the most recent update for this division from Database Manager on May 13, 2018.
Main:
  • Manuals: 2
  • Divisions: 3
  • Stops: 29
  • Registers: 7
  • Position: Console in fixed position, right.
  • Manual Compass: 61
  • Pedal Compass: 32
  • Key Action: Electrical connection from key to chest.
  • Stop Action: Electric connection between stop control and chest.
  • Console Style: Traditional style without cover.
  • Stop Controls: Tilting/rocking tablets above top manual.
  • Combination Action: Adjustable combination pistons.
  • Swell Control Type: Balanced swell shoes/pedals, AGO standard placement.
  • Pedalboard Type: Concave radiating pedalboard meeting AGO Standards.
  • Has Combination Action Thumb Pistons
We received the most recent update for this console from Database Manager on May 13, 2018.
Database Manager on February 11, 2012:

Updated through online information from Jeff Scofield. -- The organ is installed on each side of the gallery, facing down the nave; the console is located on the main floor, in the sanctuary.

We received the most recent update for this note from Database Manager on April 09, 2020.

Database Manager on August 28, 2007:

Identified by Jeff Scofield through information in Möller factory documents.

We received the most recent update for this note from Database Manager on April 09, 2020.
Source not recorded: Open In New Tab Stoplist copied from the factory specificaitons
We received the most recent update for this stoplist from Database Manager on April 09, 2020.

Instrument Images:

The database contains no images for this instrument. If you have some, please share them using the update entry button on this page.

This instrument has been viewed 147 times.