Pipe Organ Database

a project of the organ historical society

M. P. Möller (Opus 11370, 1979)

Location:

University United Methodist Church
150 E. Franklin Street
Chapel Hill, NC 27514 US
Sanctuary
Organ ID: 28928

Update This Entry

Status and Condition:

  • This instrument's location type is: Methodist Churches
  • The organ has been altered from its original state.
  • The organ's condition is good, in regular use.
We received the most recent update for this instrument's status from Database Manager on May 13, 2018.

Technical Details:

  • Chests: Electro-pneumatic (EP)
  • 44 ranks. 2,578 pipes. 6 divisions. 3 manuals. 32 stops. 64 registers.
All:
  • Chest Type(s): Electro-pneumatic (EP) chests
  • Position: In side chambers at the front of the room. No visible pipes.
We received the most recent update for this division from Database Manager on May 13, 2018.
Main:
  • Manuals: 3
  • Divisions: 6
  • Stops: 32
  • Registers: 64
  • Position: Console in fixed position, center.
  • Manual Compass: 61
  • Pedal Compass: 32
  • Key Action: Electrical connection from key to chest.
  • Stop Action: Electric connection between stop control and chest.
  • Console Style: Traditional style without cover.
  • Stop Controls: Drawknobs in vertical rows on angled jambs.
  • Combination Action: 'Hold and Set' pneumatic/mechanical system.
  • Swell Control Type: Balanced swell shoes/pedals, AGO standard placement.
  • Pedalboard Type: Concave radiating pedalboard meeting AGO Standards.
  • Has Tutti Reversible Thumb Pistons
  • Has Tutti Reversible Toe Pistons
  • Has Combination Action Thumb Pistons
  • Has Combination Action Toe Pistons
  • Has Coupler Reversible Thumb Pistons
  • Has Coupler Reversible Toe Pistons
We received the most recent update for this console from Database Manager on May 13, 2018.
Database Manager on March 09, 2011:

Updated through online information from Jeff Scofield. -- The three chancel divisions are located in side chambers; the three galley divisions are located in cases in the gallery.

We received the most recent update for this note from Database Manager on April 09, 2020.

Database Manager on September 22, 2007:

Identified by Jeff Scofield through information in Möller factory documents.

We received the most recent update for this note from Database Manager on February 11, 2019.
Source not recorded: Open In New Tab Stoplist copied from the factory specifications
We received the most recent update for this stoplist from Database Manager on April 09, 2020.

Instrument Images:

Rear gallery with twin organ cases: Photograph from a 1981 Moller brochure in the collection of James R. Stettner. Taken on 1979-06-30

This instrument has been viewed 388 times.