Pipe Organ Database

a project of the organ historical society

M. P. Möller (Opus 11298, 1978)

Location:

Church of the Good Shepherd
1401 Carrollton Ave.
Ruxton, MD 21204 US
Church
Organ ID: 29437

Update This Entry

Status and Condition:

  • This instrument's location type is: Roman Catholic Churches
  • The organ has an unknown or unreported status.
  • The organ's condition is unknown.
We received the most recent update for this instrument's status from Database Manager on May 13, 2018.

Technical Details:

  • Chests: Electro-pneumatic (EP)
  • 22 ranks. 1,202 pipes. 3 divisions. 2 manuals. 20 stops. 18 registers.
All:
  • Chest Type(s): Electro-pneumatic (EP) chests
  • Position: Pipes exposed (in whole or in part) at the front of the room.
We received the most recent update for this division from Database Manager on May 13, 2018.
Main:
  • Manuals: 2
  • Divisions: 3
  • Stops: 20
  • Registers: 18
  • Manual Compass: 61
  • Pedal Compass: 32
  • Key Action: Electrical connection from key to chest.
  • Stop Action: Electric connection between stop control and chest.
  • Console Style: Traditional style with roll top.
  • Stop Controls: Drawknobs in vertical rows on angled jambs.
  • Combination Action: Adjustable combination pistons.
  • Swell Control Type: Balanced swell shoes/pedals, AGO standard placement.
  • Pedalboard Type: Concave radiating pedalboard meeting AGO Standards.
  • Has Crescendo Pedal
  • Has Tutti Reversible Thumb Piston(s)
  • Has Tutti Reversible Toe Piston(s)
  • Has Combination Action Thumb Piston(s)
  • Has Combination Action Toe Piston(s)
  • Has Coupler Reversible Toe Piston(s)
We received the most recent update for this console from Database Manager on May 13, 2018.
Database Manager on February 21, 2010:

Updated through on-line information from Jeff Scofield.

We received the most recent update for this note from Database Manager on April 09, 2020.

Database Manager on October 06, 2007:

Identified by Jeff Scofield through information in Möller factory documents.

We received the most recent update for this note from Database Manager on April 09, 2020.
Source not recorded: Open In New Tab Stoplist copied from the factory specifications
We received the most recent update for this stoplist from Database Manager on April 09, 2020.

Instrument Images:

The database contains no images for this instrument. If you have some, please share them using the update entry button on this page.

This instrument has been viewed 45 times.